pre-poweroff-load.sh runs the same mixed, deterministic workload before every poweroff, so each observation carries identical bus exposure in both the use_ecam=1 phase and the use_ecam=0 counter-proof. It records one line per run (use_ecam, srcversion, blocks, warns, spd_ok) and keeps the full per-run output beside it, then powers the machine off by itself. Two runs of 2026-08-09 are included: without them the log is a claim.
13 lines
215 B
Plaintext
13 lines
215 B
Plaintext
start: 2026-08-09 10:38:00
|
|
end: 2026-08-09 11:01:56
|
|
use_ecam: Y
|
|
srcversion: C1EC295E03F1D2060EBBB3B
|
|
blocks: 10
|
|
spd_ok: 1
|
|
spd_serials_ref:
|
|
50e4333a
|
|
1fe43236
|
|
50e434ba
|
|
1ee433b5
|
|
driver_warnings: 0
|