docs: add §7.4 e2e test runbook for Deploy↔Setup refactor validation

Step-by-step guide to validate §7 refactor on a real VM:
Deploy stand-alone, state verification, Prepare with/without -SkipWindowsUpdate,
snapshot promotion. Includes expected values table and checklist.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
Simone
2026-05-10 07:19:27 +02:00
parent ad39aa5cf4
commit 57e4a9713e
+161
View File
@@ -0,0 +1,161 @@
# §7.4 — E2e test refactor Deploy↔Setup
Valida che il refactor §7 (2026-05-10) funzioni su VM reale:
Deploy possiede OS hardening → Setup valida senza re-applicare.
**Non toccare l'existing template** (`CI-WinBuild.vmx` + snapshot `BaseClean`).
Usare VM separata per i test.
---
## Prerequisiti
- `F:\CI\ISO\26100.1742.240906-0331.ge_release_svc_refresh_SERVER_VOL_x64FRE_en-us.iso` presente
- `F:\CI\ISO\VMware-tools-windows.iso` presente
- VMware Workstation aperto, sufficiente spazio su `F:\CI\Templates\WinBuildTest\`
---
## Step 1 — Deploy su VM test
```powershell
cd N:\Code\Workspace\Local-CI-CD-System\template
.\Deploy-WinBuild2025.ps1 `
-WinISO 'F:\CI\ISO\26100.1742.240906-0331.ge_release_svc_refresh_SERVER_VOL_x64FRE_en-us.iso' `
-ToolsISO 'F:\CI\ISO\VMware-tools-windows.iso' `
-VMXPath 'F:\CI\Templates\WinBuildTest\CI-WinBuild-test.vmx' `
-VMName 'WinBuild2025-test' `
-ProductKey 'TVRH6-WHNXV-R9WG3-9XRFY-MY832'
```
Durata attesa: 3090 min. Exit 0 = OK, snapshot `PostInstall` preso automaticamente.
Se timeout su `install_complete.flag`: aumentare `-GuestPollMaxMinutes 120`.
---
## Step 2 — Verifica stato Deploy (§7.1 + §7.2)
Sostituire `192.168.79.xxx` con IP reale della VM test (`ipconfig` dentro la VM).
```powershell
$ip = '192.168.79.xxx'
$cred = Get-Credential # Administrator / WinBuild!
$so = New-PSSessionOption -SkipCACheck -SkipCNCheck -SkipRevocationCheck
Invoke-Command -ComputerName $ip -Credential $cred `
-Authentication Basic -SessionOption $so -ScriptBlock {
"=== §7.1 Firewall ==="
Get-NetFirewallProfile | Select-Object Name, Enabled
"=== §7.2 WU services ==="
Get-Service wuauserv, UsoSvc | Select-Object Name, StartType, Status
"=== §7.2 WU GPO ==="
$au = 'HKLM:\SOFTWARE\Policies\Microsoft\Windows\WindowsUpdate\AU'
$wu = 'HKLM:\SOFTWARE\Policies\Microsoft\Windows\WindowsUpdate'
[PSCustomObject]@{
NoAutoUpdate = (Get-ItemProperty $au -EA SilentlyContinue).NoAutoUpdate
DisableWindowsUpdateAccess = (Get-ItemProperty $wu -EA SilentlyContinue).DisableWindowsUpdateAccess
}
"=== §7.1 WinRM limits ==="
[PSCustomObject]@{
MaxMemoryPerShellMB = (Get-Item WSMan:\localhost\Shell\MaxMemoryPerShellMB).Value
IdleTimeOut = (Get-Item WSMan:\localhost\Shell\IdleTimeOut).Value
}
"=== §7.1 UAC ==="
Get-ItemProperty 'HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System' |
Select-Object EnableLUA, LocalAccountTokenFilterPolicy
}
```
**Atteso**:
| Check | Valore atteso |
|---|---|
| Firewall tutti profili | `Enabled=False` |
| `wuauserv` StartType | `Manual` |
| `UsoSvc` StartType | `Manual` |
| `NoAutoUpdate` | `1` |
| `DisableWindowsUpdateAccess` | `1` |
| `MaxMemoryPerShellMB` | `>= 2048` |
| `EnableLUA` | `0` |
---
## Step 3 — Prepare -SkipWindowsUpdate (Assert-Step validation)
```powershell
.\Prepare-WinBuild2025.ps1 `
-VMIPAddress 192.168.79.xxx `
-SkipWindowsUpdate
```
**Cosa verificare nel log**:
- Step 1 (Firewall): solo `[OK]` — nessun `Set-NetFirewallProfile`
- Step 3 (WinRM): solo `[OK]` — nessun `Enable-PSRemoting``winrm set`
- Step 4b (UAC): solo `[OK]` — nessun `Set-ItemProperty EnableLUA`
- Step 5b (Explorer): solo `[OK]`
- Step 5c (CIUX): solo `[OK]`
- Step 4 (user `ci_build`): crea utente — operativo, non validation
- Step 5 (CI dirs): crea `C:\CI\{build,output,scripts}` — operativo
- Step 6: `[Setup] Skipping Windows Update` — corretto con `-SkipWindowsUpdate`
- Step 6b: disabilita wuauserv/UsoSvc — deve girare sempre
- Step 7-10: .NET, Python, VS Build Tools installati
- Final gate: tutti e 7 i check `[OK]`
- Exit code: `0`
Se un Assert-Step fallisce con `[FAIL]` su Step 1/3/4b/5b/5c → Deploy non ha applicato
quel setting → debug Deploy post-install.ps1 (controllare log nella VM).
---
## Step 4 — Prepare senza -Skip (WU lifecycle §7.2)
> Solo se Step 3 è passato. La VM deve avere internet (VMnet8 NAT).
```powershell
.\Prepare-WinBuild2025.ps1 -VMIPAddress 192.168.79.xxx
```
**Atteso**:
- Step 6 Step A: rimuove `DisableWindowsUpdateAccess` e `NoAutoUpdate` GPO keys
- Step 6 Step D: avvia wuauserv/UsoSvc/bits/cryptsvc (già Manual → solo Start)
- Step 6: WU gira via SchTask SYSTEM, ResultCode ∈ {0, 2, 3}
- Step 6b: `wuauserv StartType=Disabled`, `UsoSvc StartType=Disabled`, GPO keys re-scritti
- Final gate `Windows Update permanently disabled``[OK]`
- Exit code: `0` (o `3010` se WU richiede reboot — ripetere con `-SkipWindowsUpdate`)
---
## Step 5 — Snapshot e promozione (opzionale)
Se tutti i check di Step 3 e 4 passano:
```powershell
# Spegni VM test
& 'C:\Program Files (x86)\VMware\VMware Workstation\vmrun.exe' `
-T ws stop 'F:\CI\Templates\WinBuildTest\CI-WinBuild-test.vmx' soft
# Snapshot versionato
& 'C:\Program Files (x86)\VMware\VMware Workstation\vmrun.exe' `
-T ws snapshot 'F:\CI\Templates\WinBuildTest\CI-WinBuild-test.vmx' `
"BaseClean_$(Get-Date -Format yyyyMMdd)"
```
Per promuovere a produzione (rimpiazza template esistente):
1. Copia `F:\CI\Templates\WinBuildTest\``F:\CI\Templates\WinBuild\` (backup prima)
2. Aggiorna `GITEA_CI_TEMPLATE_PATH` in `runner/config.yaml` se path cambia
3. Aggiorna `GITEA_CI_SNAPSHOT_NAME` se usi nome versionato (vedi TODO §2.5)
---
## Checklist §7.4
- [ ] Step 1: Deploy exit 0, snapshot `PostInstall` presente
- [ ] Step 2: Firewall=False, wuauserv=Manual, NoAutoUpdate=1, MaxMemory≥2048, UAC=0
- [ ] Step 3: Prepare `-SkipWindowsUpdate` exit 0, nessun Set in Step 1/3/4b/5b/5c
- [ ] Step 4: Prepare senza `-Skip` exit 0, wuauserv=Disabled post-Step 6b