Fix emerged during §7.4 e2e test run (2026-05-10):
- Deploy: set UsoSvc to Manual explicitly (Server 2025 default = Automatic)
- Setup cleanup: re-apply Set-Service Disabled on wuauserv/UsoSvc after DISM
StartComponentCleanup (WaaSMedicSvc resets StartType during component store cleanup)
- Deploy + Setup: add Administrator autologin (AutoAdminLogon, DefaultUserName,
DefaultPassword, DefaultDomainName) in post-install.ps1; Assert-Step 5c validates it
- Add Validate-DeployState.ps1: standalone host-side check of all Deploy-set state
- Add Validate-SetupState.ps1: standalone host-side check of full post-Setup state
- Mark §7.4, §7.1 and §7.2 e2e validation items as complete in TODO.md
- Update docs: WINDOWS-TEMPLATE-SETUP.md (arch table, validation scripts section,
autologin in confine Deploy/Setup); TEST-7.4-e2e.md checklist marked done
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>