Files
local-ci-cd-system/docs/TEST-7.4-e2e.md
T
Simone 57e4a9713e docs: add §7.4 e2e test runbook for Deploy↔Setup refactor validation
Step-by-step guide to validate §7 refactor on a real VM:
Deploy stand-alone, state verification, Prepare with/without -SkipWindowsUpdate,
snapshot promotion. Includes expected values table and checklist.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-10 07:19:27 +02:00

162 lines
5.6 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# §7.4 — E2e test refactor Deploy↔Setup
Valida che il refactor §7 (2026-05-10) funzioni su VM reale:
Deploy possiede OS hardening → Setup valida senza re-applicare.
**Non toccare l'existing template** (`CI-WinBuild.vmx` + snapshot `BaseClean`).
Usare VM separata per i test.
---
## Prerequisiti
- `F:\CI\ISO\26100.1742.240906-0331.ge_release_svc_refresh_SERVER_VOL_x64FRE_en-us.iso` presente
- `F:\CI\ISO\VMware-tools-windows.iso` presente
- VMware Workstation aperto, sufficiente spazio su `F:\CI\Templates\WinBuildTest\`
---
## Step 1 — Deploy su VM test
```powershell
cd N:\Code\Workspace\Local-CI-CD-System\template
.\Deploy-WinBuild2025.ps1 `
-WinISO 'F:\CI\ISO\26100.1742.240906-0331.ge_release_svc_refresh_SERVER_VOL_x64FRE_en-us.iso' `
-ToolsISO 'F:\CI\ISO\VMware-tools-windows.iso' `
-VMXPath 'F:\CI\Templates\WinBuildTest\CI-WinBuild-test.vmx' `
-VMName 'WinBuild2025-test' `
-ProductKey 'TVRH6-WHNXV-R9WG3-9XRFY-MY832'
```
Durata attesa: 3090 min. Exit 0 = OK, snapshot `PostInstall` preso automaticamente.
Se timeout su `install_complete.flag`: aumentare `-GuestPollMaxMinutes 120`.
---
## Step 2 — Verifica stato Deploy (§7.1 + §7.2)
Sostituire `192.168.79.xxx` con IP reale della VM test (`ipconfig` dentro la VM).
```powershell
$ip = '192.168.79.xxx'
$cred = Get-Credential # Administrator / WinBuild!
$so = New-PSSessionOption -SkipCACheck -SkipCNCheck -SkipRevocationCheck
Invoke-Command -ComputerName $ip -Credential $cred `
-Authentication Basic -SessionOption $so -ScriptBlock {
"=== §7.1 Firewall ==="
Get-NetFirewallProfile | Select-Object Name, Enabled
"=== §7.2 WU services ==="
Get-Service wuauserv, UsoSvc | Select-Object Name, StartType, Status
"=== §7.2 WU GPO ==="
$au = 'HKLM:\SOFTWARE\Policies\Microsoft\Windows\WindowsUpdate\AU'
$wu = 'HKLM:\SOFTWARE\Policies\Microsoft\Windows\WindowsUpdate'
[PSCustomObject]@{
NoAutoUpdate = (Get-ItemProperty $au -EA SilentlyContinue).NoAutoUpdate
DisableWindowsUpdateAccess = (Get-ItemProperty $wu -EA SilentlyContinue).DisableWindowsUpdateAccess
}
"=== §7.1 WinRM limits ==="
[PSCustomObject]@{
MaxMemoryPerShellMB = (Get-Item WSMan:\localhost\Shell\MaxMemoryPerShellMB).Value
IdleTimeOut = (Get-Item WSMan:\localhost\Shell\IdleTimeOut).Value
}
"=== §7.1 UAC ==="
Get-ItemProperty 'HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System' |
Select-Object EnableLUA, LocalAccountTokenFilterPolicy
}
```
**Atteso**:
| Check | Valore atteso |
|---|---|
| Firewall tutti profili | `Enabled=False` |
| `wuauserv` StartType | `Manual` |
| `UsoSvc` StartType | `Manual` |
| `NoAutoUpdate` | `1` |
| `DisableWindowsUpdateAccess` | `1` |
| `MaxMemoryPerShellMB` | `>= 2048` |
| `EnableLUA` | `0` |
---
## Step 3 — Prepare -SkipWindowsUpdate (Assert-Step validation)
```powershell
.\Prepare-WinBuild2025.ps1 `
-VMIPAddress 192.168.79.xxx `
-SkipWindowsUpdate
```
**Cosa verificare nel log**:
- Step 1 (Firewall): solo `[OK]` — nessun `Set-NetFirewallProfile`
- Step 3 (WinRM): solo `[OK]` — nessun `Enable-PSRemoting``winrm set`
- Step 4b (UAC): solo `[OK]` — nessun `Set-ItemProperty EnableLUA`
- Step 5b (Explorer): solo `[OK]`
- Step 5c (CIUX): solo `[OK]`
- Step 4 (user `ci_build`): crea utente — operativo, non validation
- Step 5 (CI dirs): crea `C:\CI\{build,output,scripts}` — operativo
- Step 6: `[Setup] Skipping Windows Update` — corretto con `-SkipWindowsUpdate`
- Step 6b: disabilita wuauserv/UsoSvc — deve girare sempre
- Step 7-10: .NET, Python, VS Build Tools installati
- Final gate: tutti e 7 i check `[OK]`
- Exit code: `0`
Se un Assert-Step fallisce con `[FAIL]` su Step 1/3/4b/5b/5c → Deploy non ha applicato
quel setting → debug Deploy post-install.ps1 (controllare log nella VM).
---
## Step 4 — Prepare senza -Skip (WU lifecycle §7.2)
> Solo se Step 3 è passato. La VM deve avere internet (VMnet8 NAT).
```powershell
.\Prepare-WinBuild2025.ps1 -VMIPAddress 192.168.79.xxx
```
**Atteso**:
- Step 6 Step A: rimuove `DisableWindowsUpdateAccess` e `NoAutoUpdate` GPO keys
- Step 6 Step D: avvia wuauserv/UsoSvc/bits/cryptsvc (già Manual → solo Start)
- Step 6: WU gira via SchTask SYSTEM, ResultCode ∈ {0, 2, 3}
- Step 6b: `wuauserv StartType=Disabled`, `UsoSvc StartType=Disabled`, GPO keys re-scritti
- Final gate `Windows Update permanently disabled``[OK]`
- Exit code: `0` (o `3010` se WU richiede reboot — ripetere con `-SkipWindowsUpdate`)
---
## Step 5 — Snapshot e promozione (opzionale)
Se tutti i check di Step 3 e 4 passano:
```powershell
# Spegni VM test
& 'C:\Program Files (x86)\VMware\VMware Workstation\vmrun.exe' `
-T ws stop 'F:\CI\Templates\WinBuildTest\CI-WinBuild-test.vmx' soft
# Snapshot versionato
& 'C:\Program Files (x86)\VMware\VMware Workstation\vmrun.exe' `
-T ws snapshot 'F:\CI\Templates\WinBuildTest\CI-WinBuild-test.vmx' `
"BaseClean_$(Get-Date -Format yyyyMMdd)"
```
Per promuovere a produzione (rimpiazza template esistente):
1. Copia `F:\CI\Templates\WinBuildTest\``F:\CI\Templates\WinBuild\` (backup prima)
2. Aggiorna `GITEA_CI_TEMPLATE_PATH` in `runner/config.yaml` se path cambia
3. Aggiorna `GITEA_CI_SNAPSHOT_NAME` se usi nome versionato (vedi TODO §2.5)
---
## Checklist §7.4
- [ ] Step 1: Deploy exit 0, snapshot `PostInstall` presente
- [ ] Step 2: Firewall=False, wuauserv=Manual, NoAutoUpdate=1, MaxMemory≥2048, UAC=0
- [ ] Step 3: Prepare `-SkipWindowsUpdate` exit 0, nessun Set in Step 1/3/4b/5b/5c
- [ ] Step 4: Prepare senza `-Skip` exit 0, wuauserv=Disabled post-Step 6b